User's Manuals / Allegro Central Vacuum Compact Electric Power Brush

WESSEL-WERK EBK 280 ZAS101

Instruction Manual 

Image title

IMPORTANT SAFEGUARDS

When using an electric appliance, basic precautions should always be followed, including the following:

WARNING Please read and save this Instruction Manual.

To reduce the risk of fire, electric shock or injury:

• Do not use outdoors or on wet surfaces

•  Do not leave nozzle plugged in. Turn off the switch, place handle in up position and unplug the electric cord when not in use and before servicing. If the nozzle is not working as it should, return it to the place of purchase.

• Do not allow to be used as a toy. Close attention is necessary when used by or near children.

• Use only as described in this manual. Use only manufacturer’s recommended attachments. 

• Do not use with damaged cord or plug. If nozzle is not working as it should because it has been dropped, damaged, left outdoors, or dropped into water, return it to a service center before using. 

• Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run vacuum cleaner over cord. Keep cord away from heated surfaces.

• Do not use use extension cords or outlets with inadequate current carrying capacity. 

• Turn off all controls before unplugging

• Do not unplug by pulling cord. To unplug, grasp the plug, not the cord.

• Do not handle plug or nozzle with wet hands. 

     

• Do not put any object into vacuum intake openings. Do not use with any opening blocked. Keep vacuum intake openings free of dust, lint, hair or anything that may reduce airflow.  

•  This nozzle creates suction and contains a revolving brush roll. Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts. 

• Do not place motorized nozzle on furniture or stairs as the brush roll may cause damage. Place nozzle on floor with the handle in storage position while using attachments.

• Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.

• Belt pulleys can become hot during normal use. To prevent burns, avoid touching the belt pulley when servicing the drive belt.

• Use extra care with cleaning on stairs. 

• Do not use to pick up flammable or combustible liquids such as gasoline, or use in areas when they may be present.

• Store your nozzle indoors in a cool, dry area. 

•  Keep your work area well lighted. 

•  Unplug electrical appliances before vacuuming them. 


 

Use & Care of your Electric Nozzle 

[A] Attaching the Wessel Werk™ EBK 280 Electric Nozzle 

To attach the telescopic wand with cord management (WTCR101), simply click the wand into EBK 280 neck assembly by lining up the direct connect terminals on the powerhead with the corresponding receptacles on the wand (See Figure. 1).

Image title

The button locking mechanism will prevent the wand from coming loose from your powerhead while in use. To release the wand, depress the tab on the back of the neck assembly and pull wand free (See Figure. 2

Image title

[B] Operating Instructions

The power nozzle will automatically start when connected to working central vacuum system.  

• To achieve best results when cleaning carpet, slowly pass the power nozzle back and forth over the area to be cleaned.  
 To clean hard surfaces simply move the power nozzle over the area to be cleaned with the vacuum on and power nozzle on or off.  
 It is best to avoid cleaning carpet fringes. When it is unavoidable, place the power nozzle over the carpet and pull it toward you over the fringe.  

Image title
 

If your nozzle ceases to pick-up debris, check for an obstruction in the intake and/or neck of the power nozzle. This can be caused when excessively large or long debris, like paper, a toothpick or a sock, is lodged in the intake and/or neck area of the nozzle. 

To clear an obstruction, turn off all power supply to the nozzle. Remove the wand from the nozzle by depressing the button on the nozzle neck and pulling the wand apart (See Figure. 1). Look into the neck and remove any visible debris. Look into the intake area of the nozzle and remove any visible debris (See Figure. 4).

Image title 

Image title 

Limited Warranty 

Allegro Central Vacuum Systems, Inc. warrants that the EBK 280 Compact Electric Powerhead with Quick Disconnect, when used for household purposes, pursuant to Seller's instructions, will be free from defects in materials and workmanship for a period of three (3) years from the date if the initial consumer purchase. Allegro Central Vacuum Systems, Inc. warrants that the EBK 280 Compact Electric Powerhead with Quick Disconnect, when used in a commercial application pursuant to Seller's instructions, will be free from defects in material and workmanship for a period of ninety (90) days from the date of initial consumer purchase. This warrant is limited to the replacement of defective parts and any costs of shipping shall be incurred by the purchaser. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS, IMPLIED, OR STATUTORY, AND ALL ALLEGRO CENTRAL VACUUM SYSTEMS, INC. SPECIFICALLY DISCLAIMS RESPONSIBILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES, AND LIMITS THE IMPLIED WARRANTY OF MERCHANTABILITY TO THE PERIOD OF EFFECTIVENESS OF THIS EXPRESS WARRANTY. 